Features
New compact housing – only 61 mm long including cable glands
Temperature ranges from -40°C to 2000°C
Fully configurable via USB using Modbus protocol. Cable and software included
Peak and valley hold mode for measuring objects on conveyors
Stainless steel housing, sealed to IP65
Quick and easy installation
Use Calex or third-party software
General Specifications
Attribute | PUA2 Models | PUA5 Models | PUA8 Models
Temperature Range | LT: 45°C* to 300°C | GLT: 50°C to 1000°C | -40°C to 1000°C
| PT: 100°C to 400°C | GHT: 200°C to 1650°C |
| MT: 250°C to 1000°C | |
| HT: 450°C to 2000°C | |
Field-of-View | – 15:1 (with LT or PT temperature range) | |
| – 25:1 (with MT or HT temperature range) | |
| – 75:1 (with MT or HT temperature range) | |
| – 25:1 | | 30:1 or Close Focus ø 5 mm @ 100 mm
Output | Two-wire 4 to 20 mA (linear with temperature) | | |
Configuration | Via PC port conforming to USB 2.0 | | |
Accuracy | ±1% of reading or ±2°C, whichever is greater (PUA2 models) | | |
| ±1°C or 1% of reading, whichever is greater (PUA5 and PUA8 models) | | |
Repeatability | ±0.5% of reading or ±0.5°C, whichever is greater | | |
Emissivity Setting | Adjustable 0.1 to 1.0 via software | | |
Response Time, t90 | 200 ms | | |
Spect