Features:
Single phase / Three phase pure sine wave AC output
Hybrid System for uninterrupted power supply
Remote Monitoring System
Roof top / Ground Mountable
Application Area:
Rural Hamlets
Hospitals
Bungalows
Educational Institutions
Government Offices
Commercial Establishments
Petrol Pumps
Construction Companies
Workshops
R&D Laboratories
Water Pumps
Community Centers
Green & Reliable:
Optimized and Low maintenance system
Provide stable and reliable power increases overall efficiency of electronic components.
Export quality modules warranted for 25 Years
True MPPT (maximum power point tracking) charge controller to efficiently convert the power generated at module level.
Smart electronics to effectively manage usage of solar power based on load requirements.
High efficiency inverters capable of supplying load directly (in the day time) without storing in the batteries all the time.
Tubular/SMF/VRLA deep discharge batteries designed for longer life
Salient Features Of Off-Grid Solar Power Plants
1 KWp Off-grid Solar Power Plant can generate approximately 4-5 units in normal sunny day.
Space required for installation of 1 KWp system is approximately 100 sq ft/KWp
Smart electronics to effectively manage usage of solar power based on load requirements.
High efficiency inverters capable of supplying load directly (in the day time) without storing in the batteries all the time.
Off-grid Solar Power Plant can reduce CO2 emission by tons per year
Block Diagram & Technical Specification Hybrid Solar PCU 3 – 100 Kw
Hybrid PCU input active power factor correction as per ieee-519 standard, solar power input & wind power Input – hybrid PCU with single phase output and three phase output & load reactive power compensation .
Main Features
Load sharing between solar, Battery, Grid, Wind & DG.
100 % Utilization of solar power using Power sharing MPPT Converter and solar PCU.
Industrial Grade IGBT inverter with complete Galvanic Isolation (Three phase output –Three phase single Delta Star Transformer)
High Efficiency Temperature compensated flat cum boost charger for extended battery life.
Parallel operation for Solar, Battery and Grid.
Load side Reactive power compensation Ensures Additional output load can be used.
Solar PCU module utilizes the entire power available from solar and in the event of short-fall in power availability from solar the mains power is drawn to compensate the deficit of power.
Power sharing in PCU for catering to the load can be configured as per our requirement. Example Solar primary source and secondary for grid third for Battery.
GRID INTERACTIVE ROOF TOP SOLAR
PHOTOVOLTAIC POWER PLANT WITH NET METERING SYSTEM
Net metering is a special metering and billing agreement between utilities and their customers, whichfacilitates the connection of small, renewable energy-generating systems to the power grid. Net meteringallows residential and commercial customers who generate their own electricity from solar power to feed the excess energy back into the grid .
For example, if a residential customer has a PV system on the home’s rooftop, it may generate more electricity than the home uses during daylight hours. If the home is net-metered, the electricity meter will run backwards to provide a credit against what electricity is consumed at night or other periods where the home’s electricity use exceeds the system’s output. Customers are only billed for their “net” energy use. On average, only 20-40% of a solar energy system’s output ever goes into the grid . Exported solar electricity serves nearby customers’ loads.
Many states have passed net metering laws. Differences between states’ legislation and implementation mean that the benefits of net metering can vary widely for solar customers in different areas of the country.
Technical Specification
Hybrid PCU Rating ( kw )
3kW-100kW
MPPT Power sharing Converter
IGBT Based Active Double Boost Maximum power Tracking Converter<br>Panel DC 120 VDC to 800VDC.
Input ( Rectifier )
Active power factor correction > 0.99 with IGBT Based with power sharing configuration.
1. Nominal AC Input Voltage
3 Phase 400 V AC + Neutral + Earth
2. Line Low / High Range
320 V AC – 480 V AC
3. Frequency Range
45 Hz to 55 Hz
4. Power factor
>0.99 @ Full load
5. Efficiency ( AC- DC)
>97% @ full load
Solar power / Solar Panel
IEC 61215 Edition-1-2, IEC 61730-1 part-2, & UL 1703 Approved panels
1. Solar panel voltage@ max -Vmp (V)
250w/36vdc. 280w/36vdc. 300w/36vdc. 350w/36vdc
2. Solar panel current @max-Imp ( I )
7.22A / 7.77A / 8.33A / 9.72A
3. Solar panel power
250 w / 280 w / 300 w /350w any one series parallel combination
Wind power ( optional )
With power sharing mode
1. Wind Turbine DC Current
240 VDC to 480 VDC
2. Wind Turbine DC Current
20A to 32A
3. Wind DC Power
5kw to 7.5kw
Output ( PCU)
PWM Technology with IGBT Based / H bridge. open delta/ star transformer.
1.Voltage
3 Phase 380 -400-415 VAC + Neutral
2. Frequency ( Free running )
50 Hz ± 0.1 %
3. Output Waveform
Pure Sine Wave
Communication Interface
Standard
RS232 Port for Software Interface Optional
SNMP interface
Optional
GSM Communication with PCU
Optional
General
1.Operating Temperature
0 Deg to 40 Deg. C
2.Humidity
20 % to 95 %
3.Noise Level
< 55 dB @ 1 Meter
4.Indication –LED
Mains On, PCU On, PCU On Battery, Load On PCU, Load On Battery,
Faulty Condition, Over Temperature
5.LCD Display
Input voltage R, Y, B. Input Frequency, Output voltage R,Y,B. Output
current R, Y,B. Output frequency, Battery Voltage, Solar Panel Voltage
Solar panel current ,Battery charging discharging,
6.Audible Alarm
Mains Failure Alarm, Low Battery pre Alarm , Over Load, PCU Over
Current
7.PCU Protection
Advanced Electronic Protection for Input over Voltage, Under
Voltage, Device Safety backed with MCBs, Semiconductor Fuse,
Soft Start Feature for Rectifier and PCU converter , Battery Current
Limiting Protection, built in over load protection, IGBT Short Circuit
Protection for Rectifier and Inverter
8.Standards
IEC 61215 Edition-1-2, IEC 61730-1 part-2, & UL 1703. IEEE-519.