Technical Specifications
Single Core, Aluminium Conductor, Unarmoured
Nominal Cross Sectional Area Nominal Thickness Of Insulation Nominal Thickness Of Outer Sheath Approx. Overall Diameter Approx. Weight Of Cable Max.DC Conductor Resistance at 20°C CURRENT RATINGS
Direct in Ground In Duct In Air
2 cables 3 cables 2 cables 3 cables 2 cables 3 cables
Sq.mm mm mm mm kg/km Ohm/km Amps. Amps. Amps. Amps. Amps. Amps.
1.5 0.8 1.8 6.70 55 18.10 21 17 19 17 18 15
2.5 0.9 1.8 7.40 65 12.10 28 24 25 24 25 21
4 1.0 1.8 8.00 75 7.41 36 31 33 30 32 27
6 1.0 1.8 8.50 90 4.61 44 39 42 37 41 35
10 1.0 1.8 9.30 105 3.08 54 51 56 51 56 47
16 1.0 1.8 10.80 140 1.91 75 66 71 65 72 64
25 1.2 1.8 12.50 190 1.20 97 86 93 84 99 84
35 1.2 1.8 13.70 225 0.868 120 100 110 100 120 105
50 1.4 1.8 15.80 300 0.641 145 120 130 115 150 130
70 1.4 1.8 17.80 400 0.443 170 140 155 135 185 155
95 1.6 2.0 19.70 500 0.320 205 175 180 155 215 190
120 1.6 2.0 21.80 560 0.253 230 195 200 170 240 220
150 1.8 2.0 23.40 665 0.206 265 220 220 190 270 250
185 2.0 2.0 25.50 855 0.164 300 240 240 210 305 290
240 2.2 2.0 28.60 1070 0.125 335 270 270 225 350 335
300 2.4 2.2 32.00 1345 0.100 370 295 295 245 395 380
400 2.4 2.2 36.50 1710 0.0778 410 325 335 275 455 435
500 3.0 2.4 40.20 2150 0.0605 435 345 355 295 490 480
630 3.4 2.4 43.50 2564 0.0469 485 390 395 320 560 550
800 3.4 2.6 50.00 3270 0.0367 525 440 420 350 650 640
1000 3.4 2.8 55.00 4060 0.0291 570 490 445 380 735 720